Tuesday, December 27, 2016
Casablanca Ceiling Fan Blade Sets
*** Inventory current as of 11/03/20 ***
"Standard" blades are a 3 hole pattern and fit most Casablanca ceiling fans including: Panama, Delta, Zephyr, Victorian, Ventura, etc. "Badge" blades are a 4 hole pattern and fit Casablanca fans including: Agean, Brescia, California Zephyr, Hermosa etc. All blade set listed are new in box unless otherwise noted. Call us with any questions or to order. 952-898-2754
Cost: $40 each 5 blade set plus $10 shipping(+$2 shipping ea. addt'l set).
Qty. Item# Color Size/Type
8 B201 Maple 21" Standard
0 B202 Mahogany 21" Standard
3 B203 Sawala 21" Standard
1 B206 Dark Cherry 21" Standard
0 B207 Medium Oak 21" Standard
4 B208 Platinum 21" Standard
1 B209 Distressed White 21" Standard
0 B210 Relic 21" Standard
0 B211 Cedar 21" Standard
2 B212 Washed Birch 21" Standard
3 B213 Oil Rubbed Bronze 21" Standard
5 B214 Mocha 21" Standard
0 B515 Walnut 21" Standard
0 B520 Pine 21" Standard
3 B535 Light Oak 21" Standard
0 B536 Bleached Oak 21" Standard
0 B537 Classic White 21" Standard
0 B545 Antique Oak 21" Standard
10 B546 Weathered Pine 21" Standard
2 B547 Unfinished Ash 21" Standard
2 B548 Washed Birch 21" Standard
0 B562 Teak 21" Standard
0 B563 HighGloss Cherrywood 21" Standard
1 B564 Cherywood 21" Standard
0 B565 HighGloss Walnut 21" Standard
0 B566 HighGloss Ant. Oak 21" Standard
0 B567 HighGloss Rosewood 21" Standard
0 B583 HighGloss White 21" Standard
0 B584 HighGloss Black 21" Standard
2 B588 Matte Black 21" Standard
1 B303 Sawala 17" Standard
1 B305 Maple 17" Standard
1 B308 Navajo White 17" Standard
3 B309 Maple 17" Standard
1 B310 Weathered Pine 17" Standard
1 B312 Washed Birch 17" Standard
1 B523 HighGloss White 17" Standard
2 B539 Bleached Oak 17" Standard
2 B542 Matte Black 17" Standard
Qty Item# Color Size/Style
0 B101 Maple 21" Badge
0 B105 Architectural White 21" Badge
0 B106 Rustic Iron 21" Badge
2 B109 Platinum 21" Badge
0 B111 Relic 21" Badge
1 B501 Weathered Pine 21" Badge
1 B505 Light Oak 21" Badge
1 B506 HighGloss Cherrywood 21" Badge
2 B507 Teak 21" Badge
0 B511 Gloss White 21" Badge
1 B521 Gloss Sawala 21" Badge
1 B540 Classic White 21" Badge
0 B541 Cherrywood 21" Badge
0 BB21-WD Dark Walnut 21" Badge
1 B33B-NB Split Bamboo 21" Badge
0 B401 Maple 16" Badge
2 B411 Gloss White 16" Badge
1 B415 Antique Oak 16" Badge
1 B416 Cherrywood 16" Badge
1 B418 Teak 17" Badge
Indoor/Outdoor ABS
2 B527-21 Weathered Pine 21" Standard
0 B717 Matte White 21" Badge
1 B720 Bleached Oak 21" Badge
0 B722 Rustic Iron 21" Badge
0 B723 Architectural White 21" Badge
0 B724 Oak 21" Badge
0 B817 White 16" Badge
4 B818 Matte Black 16" Badge
0 B826 Dark Walnut 16" Badge
Qty Item# Color Size/Style
2 B552 Antique Oak 13.5" Lady Delta
1 B553 HighGloss White 13.5" Lady Delta
1 B554 HighGloss Black 13.5" Lady Delta
1 B557 HighGloss Rosewood 13.5" Lady Delta
0 B568 Classic White 16" Lady Delta
3 B572 Antique Oak 16" Lady Delta
1 B574 HighGlos Black 16" Lady Delta
1 B577 HighGloss Rosewood 16" Lady Delta
2 B41-DR Dark Rattan Wailea
1 B26S-NR Natural Rattan Wailea
1 99014 Cottage White Beadboard AB
1 B98-MP Maple Cathay Badge
1 B98-DC Dark Cherry Cathay Badge (Used)
1 B38 Light Oak 3 blade set ?
1 99009 Walnut/Burnt Walnut 25" ?
Tuesday, February 16, 2016
Fix My Casablanca Fan?
![]() |
At Fan Man Lighting we are often asked "Should I fix my Casablanca fan?".
The simple answer, in most cases, is "Yes!".
Call us at 952-683-9450 with your model and serial number for a more definitive answer on fixing your Casablanca(or any other brand).
Visit our website www.FanManLighting.com or www.FanManRepair.com for replacement parts.
Brands we service include:
Casablanca
Emerson
Fanimation
Minka Aire
Hunter
Kichler
Craftmade
Monte Carlo
Hampton Bay (Home Depot)
Harbor Breeze (Lowe's)
Turn of The Century (Menard's)
Over 30 years experience in Ceiling Fan service and sales!
The Fan Man
Thursday, November 19, 2015
Emerson SW375 or SW105 to RCK55 Conversion
![]() |
| SW375 w/ SW350 to RCK55 w/ SW605 Conversion kit |
Emerson SW375/SW105 to RCK55 w/ SW605 conversion kit(wall control)
This kit will convert older Emerson fans with the SW375 or SW105 receivers and SW350 or SW115 wall control to the current RCK55 and SW605 wall switch. You can add a hand held remote SR600.
![]() |
| SW375 w/ SR330 to RCK55 w/ SR600 Conversion kit |
Emerson SW375 / SR330 or SW105 / SR110 to RCK55 w/ SR600 Conversion kit
This kit will convert older Emerson fans with SW375 or SW105 receivers and SR330 or SR110 transmitters, to the RCK55 receiver with SR600 remote.
All kits are new Emerson parts. Instructions included, call us with any questions. 952-683-9450
www.FanManLighting.com
Tuesday, November 10, 2015
9342902000 Casablanca Stealth Glass Conversion Kit
![]() |
| www.FanManLighting.com |
Conversion pan and glass kit for ALL Casablanca Stealth model ceiling fans beginning with "32". exa: 32xxT, 32xxA, 32xxR, 32xxZ
Another exclusive item from Fan Man Lighting!
![]() |
| www.FanManLighting.com |
K190301045
Glass only for all newer Casablanca Stealth ceiling fans beginning with model number "59".
Call us at 952-683-9450 with any questions.
Fan Man Lighting
www.FanManLighting.com
Thursday, November 5, 2015
Casablanca Inteli Touch operation
Call The Fan Man with ANY questions! 952-683-9450
www.FanManLighting.com
INTELI•TOUCH OPERATION© POWER
Programmed into every Inteli-Touch Series fan is an Automatic Demonstration Program. It can be used to fully demonstrate and test the operation of the fan.To enter the demonstration program:
1. Turn off for at least three seconds. This will clear the fan memory ready for programming.
2. Turn on.
3. Immediately operate the buttons in the following sequence: FAN – LIGHT – FAN – LIGHT – FAN a multi-tone signal will verify the start of the test program which proceeds as follows:
- Lights slowly increase to full intensity.o Fan accelerates to speed three with audio tones.
- Light dims to half intensity.
- Fan accelerates to full speed with audio tones.
- Fan reverses at full speed with audio tones.
- Fan operates at full speed.
- Fan power is reversed with audio tones.
- Fan turns off with audio tones (blades coast for a short time).
- Lights turn off.
The button is normally left in the on position. Always turn the power off during cleaning or servicing the fan and during thunderstorms. It is also used to exit or enter additional programs. POWER must be left on to retain a previously set fan speed or light level.
INTELI•TOUCH OPERATION© SPEED CONTROL
FAN CONTROL ON – OFF: A momentary press of the FAN buttonCHANGE SPEED: Press and hold FAN button longer than one second
There are six individual speed settings for the fan; each speed is indicated by an audible tone of increasing pitch.
To select the desired fan speed:
1. With fan off, press and hold the button labeled . The fan blades will start rotating at the slowest speed, and will increase in steps.
2. Release the button when the desired speed is reached. The fan speed is now in memory and will automatically come on at the same speed each time the button is used. To maintain this level of speed, turn the fan on by pressing less than one second. To lower speed, turn fan off, then on by pressing and holding the button until the desired speed is reached. When the fan is on, you may increase the speed by pressing and holding the button until the desired speed is reached, then release it.
INTELI•TOUCH OPERATION© REVERSING AIRFLOW
The direction of airflow can be changed from downward to upward or from upward to downward.To reverse the airflow:
1. Make sure the is on.
2. Press the button.
Note: A four-toned signal indicates the command was accepted by the fan. A few seconds later the fan will slow to a stop and then reverse direction.
INTELI•TOUCH OPERATION© LIGHT
LIGHT CONTROL ON – OFF: A momentary press of the LIGHT buttonCHANGE BRIGHTNESS: PRESS AND HOLD LIGHT BUTTON LONGER THAN ONE SECOND
To turn the lights off and on, press and release the button for less than one second.
To vary the light brightness:
1. With lights off, press and hold the button. After one second the lights come on at their lowest level and gradually become brighter.
2. Release the button when the desired brightness level is reached. The brightness level is now in the fan memory and will automatically come on at the same brightness the next time the button is used. To maintain this level of brightness, press the button for less than one second. To lower the brightness, turn the lights off, then press and hold the button until the desired brightness level is reached.
When the light is on, you may increase the brightness level by pressing and holding the button until the desired level is reached, then release it.
AUTOMATIC DEMONSTRATION PROGRAM
The Light-Minder program automatically turns OFF the fan mounted lights after two hours.To enter the Light-Minder Program:
1. Turn the OFF for at least three seconds.
2. Turn the ON.
3. Immediately operate the buttons in the following sequence: DEMO: FAN – LIGHT – FAN – LIGHT – FAN
4. A series of tones indicates this command has been accepted. The fan and light will operate normally using the buttons to turn them on and off. But, if the lights are left on, they will automatically shut off after two hours.
To cancel the Light-Minder Program, turn the off for three seconds.
INTELI•TOUCH OPERATION© SAFE-EXIT® PROGRAM
The Safe-Exit Program gives you about thirty seconds of light when you turn the lights off, enabling you to exit your home before the lights go out.To enter the Safe-Exit Program:
1. Turn the off for at least three seconds.
2. Turn the on.
3. Immediately operate the buttons in the following sequence: SAFE EXIT: FAN – FAN – LIGHT – LIGHT
After you hear the confirming audio tones from the fan – immediately press
4. The lights will blink to indicate this command has been accepted. The lights will stay on for twenty seconds and then begin to dim. After a total of thirty seconds has elapsed, the lights will be off completely.
To cancel the Safe-Exit Program, turn the off for three seconds.
INTELI•TOUCH OPERATION© HOME-SAFE® PROGRAM
The Home-Safe Program makes an unoccupied home appear occupied by turning the lights on and off at random times.To enter the Home-Safe Program:
1. Turn the off for at least three seconds.
2. Turn the on.
3. Immediately operate the buttons in the following sequence: HOME SAFETY: LIGHT – FAN – LIGHT – FAN
4. A tone and flashing light indicate this command has been accepted. This program overrides all manual control of lights and fan. The lights will now be automatically cycled on and off in a controlled sequence as follows: On 1 hour, off 1/2 hour, on 2 hours, off 1 hour, on 1/2 hour then off 2 hours. This seven hour pattern will repeat continuously so that a different pattern of lighting is seen each day of the week.
To cancel the Home-Safe Program, turn the off for three seconds.
INTELI•TOUCH OPERATION© FAN-MINDER™ PROGRAM
The Fan-Minder feature will add to your comfort when used in the bedroom. The program reduces the speed of the fan each two-hour interval to compensate for the cooling night air.To enter the Fan-Minder Program:
1. Turn the off for at least three seconds.
2. Turn the on.
3. Immediately operate the buttons in the following sequence: FAN MINDER: LIGHT – LIGHT – FAN – FAN
4. The fan controller will respond with three descending tones. A timer is now initiated and the fan will reduce one speed for each two-hour interval. The fan will not, however, descend below the second lowest speed.
To cancel the Fan-Minder Program, turn the off for three seconds. You may increase the fan speed by pressing and holding the button until the desired speed is reached, then release it. The fan will again reduce one speed for each 2 hour interval.
INTELI•TOUCH OPERATION© LIGHT-MINDER® PROGRAM
Note: Both Light-Minder and Safe-Exit programs can run at the same time, however the dimmer cannot be used, the light may only be turned ON/OFF.NO FAN OR LIGHT –
Check main circuit fuses, curcuit breakers, or wall switch position. Check all wire connections, making sure the power is turned off during this inspection.
FAN WOBBLES –
Be sure canopy pin is properly set into the slot on the ball
SHAKES EXCESSIVELY –
Check the screws holding the blade holders to the fan motor. Tighten as necessary.·
Check the angle of the blades to make sure that a blade holder has not been bent during installation.
FAN NOISY DURING OPERATION –
Check and tighten light fixture retaining screws, glass shade screws and/or the light bulb(s).
Tighten canopy screws and mounting plate assembly.
Tighten the blade to bladeholder screws and blade holders to flywheel.
Make sure all screws in the motor housing are snug, but not overly tight.
Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have fallen off the wire splices. Tighten or adjust as necessary.
BREAK-IN PERIOD –
Let fan run at high speed for two (2) hours
DOES NOT RUN ON LOW –
If new, “break-in” may be required – run at higher speed for several days
SPEED LIGHTS FLASH OR BLINK DURING OPERATION OF W-32 WALL CONTROLS/FAN MAY ROTATE OR MAKE AUDIBLE TONES DURING OPERATION OF THE W-11 AND W-12 WALL CONTROLS: Normal operation.WHEN AC POWER IS TURNED ON FOR THE FIRST TIME, THE LIGHTS OPERATE NORMALLY, BUT W-32 WALL CONTROL OPERATION IS REVERSED: FAN BUTTON OPERATES THE LIGHTS; LIGHT BUTTON OPERATES THE FAN: Reverse the 2 black and white striped wire connections.FAN OR LIGHTS APPEAR TO OPERATE BY THEMSELVES (CHANGING SPEED OR INTENSITY), WALL CONTROL OPERATION IS INTERMITTENT: Check AC supply for irregularities, (noise spikes, fluctuations, or failure); or circuit board assembly.
Call The Fan Man with ANY questions! 952-898-2754
www.FanManLighting.com
Saturday, May 16, 2015
Casablanca's "New Platform" or "Universal Remote" system.
![]() |
| Casablanca K0223-01 www.FanManLighting.com |
![]() |
| Casablanca 99020 www.FanManLighting.com |
Wall control: K022301000 (K0223-01)
Hand Held control: 99020
Receiver: K021906000 (K0219-06) If Your Fan Remote System is Acting Up eg: Fan Speed Problems or Light Problems This is Usually the Failure Point, More So than the Transmitter.
Call us with any troubleshooting questions. 952-683-9450
Fan Man Lighting
www.FanManLighting.com
15465 Cedar Ave
Apple Valley, MN. 55124
Labels:
99020,
Casablanca,
K0219-06,
K021906000,
K0223-01,
K022301000,
New Platform
Monday, January 14, 2013
Casablanca Inteli-Touch 3 Conversion kits
![]() |
| Casablanca G265802000 FanManLighting.com |
The kits listed below provide everything needed to convert older Casablanca Inteli-Touch ceiling fans to the new Inteli-Touch 3 system. Follow the links to our main website, or call the store with any questions.
Inteli-Touch 3 conversion kits.
Kits include circuit board, wall control, and conversion plugs.
G265802000 or IT3Kit For most Casablanca Inteli-Touch Fans 1987 & newer including Panama(12XXXT & 66XXT), Victorian(2XXXT & 63XXT) and many other models. Kit includes: 8880602000 circuit board, W-85 wall control and 7731901000 conversion plug.
G265803000 or IT3Kit-S For Casablanca Inteli-Touch fans Stealth(32XXT), Bel Air(38XXT), and Venus(24XXT) models. Kit includes: 8907101000 circuit board, W-85 wall control and 7731901000 conversion plug.
G265805000 or IT3Kit-M For Casablanca Inteli-Touch fans Mission(970XXT), Cathay(98XXT), and Nouvelle(96XXT) models. Kit includes: 8880603000 circuit board, W-85 wall control, and 7731901000 conversion plug.
IT3Kit-86 For Casablanca Inteli-Touch fans 1986 & Older including Zephyr(1XXXT), Older Panama, 4 Seasons, and Victorian models. Kit includes: 8880602000 circuit board, W-85 wall control and P-FM2011-3 and
P-FM2011-2 conversion plugs.
Call us with your model and serial number.
Fan Man Lighting
952-683-9450
www.FanManLighting.com
www.FanManRepair.com
Subscribe to:
Posts (Atom)